Mirror

EventLog change notification in real-time (Views: 706)


Problem/Question/Abstract:

I needed a way to be notified in real-time when someone acceded my computer inside an intranet. After doing some research, the solution would pass by using the Security event log that is used when you activate any audit option.

Answer:

In the Control Panel\Administrative Tools\Local Security Police\Local Polices\Audit Police I could audit various account events; in my case I was specially looking for 'Audit account logon events' and 'Audit logon events'.
After setting up these to audit success events, I could confirm that 'Security event log' really logs these attempts. But, how could I be notified by the system when a new event was added to the event log?

The timer - newbies solution

The first solution would be to use a timer that would check the event log count every second, and if the count was different from the last one the log has changed.

To test this we need to create a new project. Declare in the private part of the form the following:

private
{ Private declarations }
FLastCount: Integer; // last event log count
FLog: THandle; // handle to the opened log

Because to work with the log we need to open it first, we do that in the Button1.Click;

procedure TForm1.Button1Click(Sender: TObject);
begin
  FLog := OpenEventLog(nil, PChar('Security'));
  Timer1.Enabled := True;
end;

And now we only need to check the event log count

procedure TForm1.Timer1Timer(Sender: TObject);
var
  lCount: Cardinal;

begin
  if GetNumberOfEventLogRecords(FLog, lCount) and (lCount <> FLastCount) and (lCount >
    0) then
  begin
    FLastCount := lCount;
    ListBox1.Items.Add('Changed at ' + DateTimeToStr(Now()));
  end;
end;

If we are pragmatic we know that this solution works in spite of the fact that there is a little problem. We know that if this were the best solution, I wouldn't be here writing this article ;)

Event object - professional solution

In the Win32 API under the event log group we can find a function that can help us detecting when the event log changes.
The NotifyChangeEventLog function lets an application receive notification when an event is written to the event log file specified by the hEventLog parameter.
When the event is written to the event log file, the function causes the event object specified by the hEvent parameter to become signaled.

Great, this is exactly what we want. But, what is an event object?
An event object is a object that can be created to signal operations between different system processes. The event object is under the same category has Mutex, Process and Semaphores.

To create an event object we use the CreateEvent function, which creates a named or unnamed event object.

The code to test this new option is:

private
{ Private declarations }
FLog: THandle; // handle to the opened log
FEvent: THandle; // handle to the event object

procedure WaitForChange;

procedure TForm1.Button1Click(Sender: TObject);
begin
  FLog := OpenEventLog(nil, PChar('Security'));
  FEvent := CreateEvent(nil, True, False, nil); // create unnamed object
  NotifyChangeEventLog(FLog, FEvent); // start the event log change notification

  WaitForChange;
end;

The way we have to check if a existent event object is signaled or not is by using the WaitForSingleObject function. This function returns when one of the following occurs:
the specified object is in the signaled state.
the time-out interval elapses.

Because, we don't know when the log changes we will not use a time-out interval, so the only way of this function returns is when the event object is in the signaled state.

So, we will need a way of having a loop, which will be constantly calling WaitForSingleObject when it returns. This is the job for the recursive WaitForChange method.

procedure TForm1.WaitForChange;
var
  lResult: Cardinal;

begin
  // reset event signal, so the system can signal it again
  ResetEvent(FEvent);
  // wait for event to be signalled
  lResult := WaitForSingleObject(FEvent, INFINITE);
  // check event result
  case lResult of
    WAIT_OBJECT_0:
      begin
        ListBox1.Items.Add('Changed at ' + DateTimeToStr(Now()));
        Application.ProcessMessages;
      end;
  end;

  // wait for change again
  WaitForChange;
end;

As you have noticed, this solution has a big problem. The application stops responding, but why? Well, WaitForSingleObject function checks the current state of the specified object. If the object's state is non signaled, the calling thread enters an efficient wait state. The thread consumes very little processor time while waiting for the object state to become signaled or the time-out interval to elapse.
Unfortunaly the 'efficient wait state' makes the calling thread being as it was sleeping... sleeping as a rock!

If we didn't need to have an available interface, we could end here. But we need to have a working interface, at least to close the application.

The only solution to our case is to have a secondary thread, which will do this wait, and will call an event of the main thread when a change occurs.

The main code for this thread is:

procedure TNotifyChangeEventLog.Execute;
var
  lResult: DWORD;

begin
  while (not Terminated) do
  begin
    // reset event signal, so we can get it again
    ResetEvent(FEventHandle);
    // wait for event to happen
    lResult := WaitForSingleObject(FEventHandle, INFINITE);
    // check event result
    case lResult of
      WAIT_OBJECT_0: Synchronize(DoChange);
    else
      Synchronize(DoChange);
    end;
  end;
end;

The complete project

Because I needed more things than just to know if the event log changed or not, I ended up by creating a component to work with the event log.
This component is not just another event log component, because it incorporates more things than the usual: read event log, change notifications, functions to scroll the event log (First, Last, Eof, Next).

At this moment I've already sent this component to be approved for incorporating the JVCL (JEDI VCL) at http://jvcl.sourceforge.net
Because it steel wasn't approved I included it with this sample.

Final notes

Why all this trouble to use the event object solution if the timer solution was enough? The problem is that the event object solution is safer.

For example, if you wanted to use the RegNotifyChangeKeyValue function that notifies the caller about changes to the attributes or contents of a specified registry key.
What you would do? You're right, it would almost impossible to use a timer, and would be so simple to use an event object.