| No. B232Z | |
| Additional Light
Barrier for Infrared Stopwatch | |
| Additional light
barrier to the kit "Infrared Stopwatch B232". By means of this extension
it is possible to operate the infrared stopwatch B232 with 2 light
barriers: 1 barrier each at the start and finish. Operating voltage:
9V=. | |
|
Mounting instructions:
Assemble the board according to the parts list
and assembly print. Please observe in particular the following: |
| Setting into
operation:
Connect the receiving module with the receiving
module in the basic kit B232 in parallel by means of a cable. Cable’s
lengths of up to 50 meters are possible. In countries where the
CE-regulation applies, however, only cable’s length of up to 3 meters may
be used (see "Measures concerning the CE-conformity"). Please use a cable
that is stable enough (3 conductors) which should be shielded (against
interfering impulses from the outside). Connect the shielding of the cable
with the negative pole of the battery of the receiver. Then mount the
infrared transmitter opposite the receiver as described in B232, too.
| |
| |
| |
| |
| |
| |
| Gold-plated boards! Fitting cases: Transmitter: KEMO G081 Receiver: KEMO G081 Price group: 7 | |
Technical data Operating voltage + current: transmitter: 9V=
< 100mA, Receiver: 9V= < 20mA Circuit description The system consists of an infrared transmitter and an infrared receiver. A voltage impulse is produced in the infrared receiving module, if the light barrier is interrupted (if somebody walks through the invisible ray of light). This impulse starts or stops the stopwatch (if the watch is operational, that means, if the key S1 was pressed before).
These operating instructions belong to this
product. They contain important instructions for operation and handling.
Please keep this in mind when passing the product on to another
person.
The system consists of an infrared transmitter and an infrared receiver. A voltage impulse is produced in the infrared receiving module, if the light barrier is interrupted (if somebody walks through the invisible ray of light). This impulse starts or stops the stopwatch (if the watch is operational, that means, if the key S1 was pressed before).
This kit is maintenance-free. If this device has to be disposed of one day, please hand it over to the special waste collection where "electronic systems" are collected, i.e. where computers, television sets etc. are disposed of, too. Please do not dispose of with the household waste! | |